Skip to main content

Data structure

Access EUDAMED Market Surveillance (Playground) or EUDAMED Market Surveillance (Production).

Note

With Release 2.27.0, the Market Surveillance module is available in EUDAMED Production environment.

Please note that the Vigilance and CIPS modules, visible on some of the screens within the steps described in this user guide are only available in EUDAMED Playground environment.

Procedure characteristics

Unacceptable Risk (UNR) must include at least one corrective action at submission, linked to one or more Economic Operator(s) (EO) and one or multiple devices.

Measures from the initiating CA should only be registered in EUDAMED after the period has passed for the EO to take adequate corrective action when EO did not comply with the requirements.

Other CAs may also add measures and additional information, but they can only object to the initiating CA's measure(s),

Other Non-Compliance (ONC) does not require corrective action(s) and must link to one or multiple EOs and one or multiple devices.

There must be at least one measure linked to the procedure before it can be submitted.

There is no possibility of registering objections on measures for ONC.

Preventive Health Protection (PHP) follows the same rules as ONC. The only difference for the device scope type is that the category can be used for preventive health protective measures while for ONC and PHP it is not an option.

Procedure and linked items:

Procedure type

Linked Corrective action(s) – by initiating CA?

Linked Measure(s) – by initiating CA?

Other CA can add Measure?

Other CA can add Additional information?

If linked measure: other CA can object?

EO

Device

UNR

At least one at submission – cannot be added afterwards

Only when Procedure = Open (i.e. can only be added after submission)

Yes

Yes

Yes, but only within two months of first submission of measure by initiating CA (cannot object to measure by other CA)

=/>1

=/>1

ONC

No

At least one at submission; cannot be added afterwards

No

No

No

=/>1

=/>1

PHP

No

At least one at submission; cannot be added afterwards

No

No

No

=/>1

=/>1

EUDAMED infographic icon INFOGRAPHIC: MSU procedure processes

EUDAMED msu procedure processes infographic

Who has access

The main actor in the Market Surveillance (MSU) module is the Competent Authority. CA users must request access to the CA to which they belong.

A slim viewer profile is assigned by default to the MSU users for Vigilance and CI/PS.

A Notified Body (NB) referenced in a procedure is notified once the procedure is submitted and will have read-only access to the record via theSearch & ViewSearch & View page.

A Designating Authority (DA) can request access to MSU in order to be informed of new measures referencing the NB(s) they supervise.

Economic Operators and Sponsors have no access to the MSU module.

The icon indicates the fields the NB will not view:

EUDAMED lock icon indicates that the field in not accessible to nb referenced in the procedure